100ton Water Chiller Central Air Conditioner Air Cooled Screw Type

Product Details
Customization: Available
Type: Air-Cooled
Cooling Method: Air-cooled
Still deciding? Get samples of US$ 5000/Piece
Request Sample
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2011

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
76
Year of Establishment
2004-12-28
  • 100ton Water Chiller Central Air Conditioner Air Cooled Screw Type
  • 100ton Water Chiller Central Air Conditioner Air Cooled Screw Type
  • 100ton Water Chiller Central Air Conditioner Air Cooled Screw Type
  • 100ton Water Chiller Central Air Conditioner Air Cooled Screw Type
  • 100ton Water Chiller Central Air Conditioner Air Cooled Screw Type
  • 100ton Water Chiller Central Air Conditioner Air Cooled Screw Type
Find Similar Products

Basic Info.

Model NO.
HWAL
Selected Voltage
380V/50HZ
Compressor Number
2
Noise Level
Ultra Low
Application Fields
Pharmaceutical
Application Machine
Combination machine
Certification
ISO, CE
Condition
New
Product Name
Hotel Villa Water Chiller Central Air Conditioner
Cooling Capacity
150-1192kw
Heating Capacity
185-1400kw
Transport Package
Stretch Roll Film, EPE, Wooden Package
Specification
Customize
Trademark
Head-Power
Origin
China(Mainland)
Production Capacity
600 Sets/Month

Product Description

Hotel Villa Water Chiller Central Air Conditioner Air Cooled Screw TYpe Specifications:
Cooling only type;
Screw compressor
Chilled outlet/inlet water temp. 7/12 degree.
Cooling capacity:150~1900kw.
R22
Features:
1. Superior Performance: international advanced semi-closed screw compressor; several  refrigerant circuits insure no stop when one circuit needs maintenance; low noise; efficient heat transfer;
2. Unique High Temperature Type Chiller
3. Easy Installation: compact structure, take up limited space; refrigerant has been filled in the chiller so as to save time and expenses;
4. Low Cost for Operation and Maintenance;
5. Comprehensive Security Protection: high and low pressure protection, electric motor protection, safety valve protection, all the above protections ensure the unit safe and stable in operation.
6. Optional device: partial or total heat recovery system
7. Cooling capacity: 150~1900kw.
  
product features
 Superior performance
Adopt world famous semi-hermetic screw compressor, integrate motors and compressors, no refrigerant leakage.
When there are several compressors, the control system will start and stop them by turns, balance the load of all components in order to prolong the life of unit .
The units always has several refrigerant circuits, when one of them needs maintenance, the rest can also work normally.
 The compressor adopts unloading and step-down voltage starting method to avoid the impact of power system.
Ultra-low noise design of turbine blades.
V-type structural design, good cooling effect.
Unique high-temperature-type unit
High-temperature heat pump unit can provide maximum 55-60 ºC hot water for heating, and also sanitary hot water. The idea of "big difference, small flow" is in line with energy saving which we always place at first place.
Easy installation
Compact structure,take up small area, save room space.
The machine has been filled with R22 refrigerant and lubricant when it is finished in the factory, so it reduces installation time and costs.
Little vibration, and the installation of vibration isolation is easy.
You just need to connect water pipes to the evaporator when in installation..
Low operation and maintenance costs
 The unit can realize intelligent control in accordance with load demand: four-step(100%, 75%, 50%, 25%) capacity adjustment are available, thus when the unit is working under partial loading conditions, it can save energy to a large extent.
The total parts of screw compressor has only 1/10 of reciprocating compressor, simple structure, less wearing parts, no inlet/oulet valves, so it has a very low failure rate.
The screw compressor can work up to 40,000 hours trouble-free .
Security measures
Pressure protection: high pressure and low pressure protection device.
Motor Protection: loss of voltage protection, lack of phase protection, reverse-phase protector, internal overheat protector.
Anti-frozen protection: When the chilled water temperature is too low, the unit will stop.
Safe valve protection: When the refrigerant pressure exceeds a certain value, the safe exhaust valve will automatically open.
All the above protection measures assure the unit safe and stable.
 
Air Cooled Screw Water Chillers(with heat recovery)
Model Number HWALR150 HWALR200 HWALR250 HWALR330 HWALR400
Cooling Capacity KW 150 182 245 322 388
Heating Capacity KW 185 212 285 380 445
Cooling Power Input KW 48.2 57.7 76 99 118
Heating Power Input KW 47 56 74 97 113
Power Supply 380V/3N~50Hz
Energy Control 0~25~50~75~100% / Infinitely Variable Control
Compressor Type 6+7 Semi-closed Double Screw Type
Number 1 1 1 1 1
Refrigerant Type R22 (other refrigerant systems(R407C,etc) are available too.)
Way of Throttling External Balance of Thermal Expansion Valve/ Electronic Expansion Valve
Refrigerant Volume  kg 48 62 74 85 115
Heat Exchanger of Air Side Internal Thread Copper Tube with Aluminium Fin
Condensing Fan Type   Ultra-low Noise Axial Fan
Power KW 1.1*4 1.5*4 1.5*6 1.5*8 1.5*10
Heat Exchanger of Water Side Type   Dry Shell and Tube 
Cooling Water Flow m³/h 26 32 43 56 67
Heating Water Flow m³/h 28 37 49 66 77
Connection Pipe   DN80 DN80 DN100 DN100 DN100
Water Resistance KPa 50~60
Partial Heat Recovery Heating Capacity KW 55 65 86 114 135
Hot Water Volume m³/h 15.7 18.6 24.6 32.6 38.7
Total Heat Recovery Heating Capacity KW 158 180 245 325 380
Hot Water Volume m³/h 45 52 90 93 109
Noise Level dB/A 64 64 65 65 66
Dimensions Length mm 2300 2500 3400 4400 5400
Width mm 2200 2250 2250 2250 2250
Height mm 2200 2250 2250 2250 2250
Notice: 1. Nominal cooling condition:  inlet/outlet water temperature is 12/7ºC, the air dry/wet bulb temperature is 35/24ºC; 
2. Nominal heating condition:  inlet/outlet water temperature is 40/45ºC, the air dry/wet bulb temperature is 7/6ºC.
3. The water supply of heat recovery refers to the water volume when the water temperature increases from 20ºC to 50ºC. 

100ton Water Chiller Central Air Conditioner Air Cooled Screw Type100ton Water Chiller Central Air Conditioner Air Cooled Screw Type100ton Water Chiller Central Air Conditioner Air Cooled Screw Type100ton Water Chiller Central Air Conditioner Air Cooled Screw Type100ton Water Chiller Central Air Conditioner Air Cooled Screw Type100ton Water Chiller Central Air Conditioner Air Cooled Screw Type100ton Water Chiller Central Air Conditioner Air Cooled Screw Type




 