Customization: | Available |
---|---|
Type: | Air-Cooled |
Cooling Method: | Air-cooled |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Model Number | HWALR150 | HWALR200 | HWALR250 | HWALR330 | HWALR400 | HWALR500 | HWALR600 | HWALR500D | HWALR650 | HWALR800D | HWALR1000D | HWALR1200D | ||
Cooling Capacity | KW | 150 | 182 | 245 | 322 | 388 | 498 | 596 | 490 | 645 | 776 | 996 | 1192 | |
Heating Capacity | KW | 185 | 212 | 285 | 380 | 445 | 566 | 683 | 570 | 760 | 890 | 1112 | 1366 | |
Cooling Power Input | KW | 48.2 | 57.7 | 76 | 99 | 118 | 148 | 183 | 252 | 198 | 236 | 296 | 366 | |
Heating Power Input | KW | 47 | 56 | 74 | 97 | 113 | 144 | 178 | 248 | 194 | 226 | 288 | 356 | |
Power Supply | 380V/3N~50Hz | |||||||||||||
Energy Control | 0~25~50~75~100% / Infinitely Variable Control | |||||||||||||
Compressor | Type | 6+7 Semi-closed Double Screw Type | ||||||||||||
Number | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 2 | 2 | 2 | 2 | 2 | ||
Refrigerant | Type | R22 (other refrigerant systems(R407C,etc) are available too.) | ||||||||||||
Way of Throttling | External Balance of Thermal Expansion Valve/ Electronic Expansion Valve | |||||||||||||
Refrigerant Volume | kg | 48 | 62 | 74 | 85 | 115 | 145 | 162 | 162 | 171 | 230 | 290 | 324 | |
Heat Exchanger of Air Side | Internal Thread Copper Tube with Aluminium Fin | |||||||||||||
Condensing Fan | Type | Ultra-low Noise Axial Fan | ||||||||||||
Power | KW | 1.1*4 | 1.5*4 | 1.5*6 | 1.5*8 | 1.5*10 | 1.5*12 | 1.5*14 | 1.5*12 | 1.5*16 | 1.5*20 | 1.5*24 | 1.5*28 | |
Heat Exchanger of Water Side | Type | Dry Shell and Tube | ||||||||||||
Cooling Water Flow | m³/h | 26 | 32 | 43 | 56 | 67 | 86 | 102.5 | 85 | 111 | 135 | 172 | 223 | |
Heating Water Flow | m³/h | 28 | 37 | 49 | 66 | 77 | 98 | 118 | 99 | 131 | 155 | 192 | 235 | |
Connection Pipe | DN80 | DN80 | DN100 | DN100 | DN100 | DN125 | DN125 | DN125 | DN150 | DN150 | DN150 | DN200 | ||
Water Resistance | KPa | 50~60 | ||||||||||||
Partial Heat Recovery | Heating Capacity | KW | 55 | 65 | 86 | 114 | 135 | 170 | 205 | 170 | 230 | 268 | 335 | 410 |
Hot Water Volume | m³/h | 15.7 | 18.6 | 24.6 | 32.6 | 38.7 | 49 | 59 | 49 | 66 | 77 | 96 | 118 | |
Total Heat Recovery | Heating Capacity | KW | 158 | 180 | 245 | 325 | 380 | 480 | 580 | 485 | 646 | 756 | 945 | 1160 |
Hot Water Volume | m³/h | 45 | 52 | 90 | 93 | 109 | 138 | 166 | 139 | 185 | 217 | 270 | 320 | |
Noise Level | dB/A | 64 | 64 | 65 | 65 | 66 | 66 | 67 | 68 | 68 | 69 | 70 | 71 | |
Dimensions | Length | mm | 2300 | 2500 | 3400 | 4400 | 5400 | 6400 | 7400 | 6400 | 8400 | 10500 | 6400*2 | 7400*2 |
Width | mm | 2200 | 2250 | 2250 | 2250 | 2250 | 2250 | 2250 | 2250 | 2250 | 2250 | 2250 | 2250 | |
Height | mm | 2200 | 2250 | 2250 | 2250 | 2250 | 2250 | 2250 | 2250 | 2250 | 2250 | 2250 | 2250 | |
Notice: 1. Nominal cooling condition: inlet/outlet water temperature is 12/7ºC, the air dry/wet bulb temperature is 35/24ºC; | ||||||||||||||
2. Nominal heating condition: inlet/outlet water temperature is 40/45ºC, the air dry/wet bulb temperature is 7/6ºC. | ||||||||||||||
3. The water supply of heat recovery refers to the water volume when the water temperature increases from 20ºC to 50ºC. | ||||||||||||||
4.other refrigerant systems(R407C,etc) are available too. | ||||||||||||||
5. The above dimensions are just for reference, they maybe modified due to improvement. |