Smaller Sizes Type Heat Recovery Fresh Air Handling Unit

Product Details
Customization: Available
Type: Heat Recovery Fresh Air
Air Tube Material: Galvanized Sheet
Still deciding? Get samples of US$ 1/Piece
Request Sample
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2011

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

to see all verified strength labels (19)
  • Smaller Sizes Type Heat Recovery Fresh Air Handling Unit
  • Smaller Sizes Type Heat Recovery Fresh Air Handling Unit
  • Smaller Sizes Type Heat Recovery Fresh Air Handling Unit
  • Smaller Sizes Type Heat Recovery Fresh Air Handling Unit
  • Smaller Sizes Type Heat Recovery Fresh Air Handling Unit
  • Smaller Sizes Type Heat Recovery Fresh Air Handling Unit
Find Similar Products

Basic Info.

Model NO.
ZQH/ZKZseries
Corrosion Durability
Ultrahigh
Operating Voltage
380/400 VAC
Noise Level
Low
Application Fields
Food Processing
Mounting
Ceiling Mount
Lifetime
15~20 years
Certification
ISO, CE, ETL, CCS
Condition
New
Transport Package
Plastic Foam+Wooden Case Packaging
Specification
1500x800x1000mm
Trademark
Head-Power
Origin
Foshan, Guangdong, China
HS Code
8414599099
Production Capacity
200 Set/Sets Per Month

Product Description

1) The Feature of China Heat pump heat recovery fresh air handling unit 
a.Hig-grad configuration, reliable running
Global famous fully-closed scroll compressor is used;external balance thermostiatic expansion valve,solenoid valve and other refrigerating parts of renowned brands are adopted.
b.Fully fresh air ,high air quality
Fresh air coming  from the outdoors can be directly treated by the unit, and polluted indoor air due to human activities and building materials can be exhausted;freshair ,exhaust air channel heat exchange not only meet air conditioning requirements,but also ensures the absolute fresh air,fundamentally prohibiting cross contamination of air,and ozone disinfection UV germicidal lamp and high static pressure dust removal device are also optional.
c.Independent fresh air refrigerating system
Compared to conventional chilled water systems,the evaporation temperature of the unit is 8-10ºC higher,and second heat exchange for the transfer of chilled water is not needed,enhancing refrigerating efficiency by at least 30%.
d.Cooling tower and outdoor unit not needed
Using pipe-piece evaporation condensation technology,make fulluse of fin surface evaporation of water film through the mass transfer and heat transfer can be realized within the refrigerant condenser cooling cold film,crew integration,structural design,no outdoor unit without the need for cooling towers and high-power cooling pumps,fans,pumps and engineering of distribution power.
e.Patented all heat recovery technology having heat recovery efficiency at least 85% and evaporative condensation units up to 92%
Low-temperature low-humidity indoor exhaust air is used as the cooling air of the evaporative condenser,which not only uses the sensible heat(temperature difference)of the indoor air exhaust heat,but uses the latent heat(humidity difference),ensuring  condensation effect is greatly better than that of the direct using outdoor air for cooling,preventing the energy loss due to air displacement and ventilation.Likewise,during heating of the unit, the high or low-temperature air exhausted from indoors can be used as the heat exchange souce at teh side of the evaporator.Compared with traditional central air conditioningsystems, it saves energy for about 50%.
f.Condensed water discharge system not needed(unique for evaporative condenser)
The condensed water coming from fresh air evaporation and to be treated can be directly introduced into the air exhaust condensation system of the unit a the cooling water,without the use of condensed water discharge system.Because lower condensed water temperature,not only the cooling capacity can e recovered,but the advanced film-type water cooling method can be utilized, enabling the cooling method can be utilized,enabling the cooling water to sufficiently wet the condensing fins,reinforce the heat exchange of condensing plate,and effectively overcome the scale phenomenon due to the water film on the fin liable to "dry point"
g.Independent ventilating system not needed
In the transitional seasons, fresh air can be used to bear indoor load,and only the supplying and exhaust fans are run to achieve automatioc air exchange,without starting the compressor,meanwhile it's no need of an independent air exchange system,greatly saving energy.
h.Advanced control,safe and reliable
All chinese LCD interface and microcomputer intelligent controller are adopted, have advanced control and completer functions;mechanical and electrical integrated design achieves unit start/shutdown program management,timing control,failure warning and fault self-diagnosis and other functions;the controller boasts optimal automatic control and power ful anti-interference capacity;multiple protections for e.g lack of phase ,phase sequence and unbalance,compressor overload,start delay, and abnormal air suction and discharge pressure,ans so on, ensuring running safety.Significantly lower initial investment.

2) Product model

 Heat Recovery Fresh Air Handling Unit
Model Number HAX015 HAX025 HAX030 HAX040 HAX050 HAX060 HAX070 HAX080 HAX100 HAX120 HAX150 HAX180 HAX200 HAX250 HAX300 HAX350
Cooling Capacity KW 9 12 16 19 23 28 33 36 46 56 69 80 92 112 138 167
Heating Capacity KW 9.5 12.6 16.7 20 24.3 30 35 39 49 60 73 85 98 120 148 180
Voltage 220V~50HZ 380V/3PH~50HZ
Refrigerant R22
Fresh Air System Air Flow m³/h 1500 2500 3000 4000 5000 6000 7000 8000 10000 12000 15000 18000 20000 25000 30000 35000
External Static Pressure Pa 80 100 120 150 180 180 220 240 240 250 300 350 400 420 480 500
Motor Power KW 0.3 0.55 0.75 0.75 1.1 1.5 2.2 2.2 3 4 4 5.5 7.5 7.5 11 15
Discharge Air System Air Flow m³/h 1500 2500 3000 4000 5000 6000 7000 8000 10000 12000 15000 18000 20000 25000 30000 35000
External Static Pressure Pa 80 100 120 150 180 220 240 250 280 300 350 400 430 450 520 550
Motor Power KW 0.3 0.55 0.75 0.75 1.1 1.5 2.2 2.2 3 4 4 5.5 7.5 7.5 11 15
Heat Exchange Efficiency >87%
Compressor Type   Rotor Type Flexible Hermetic  Scroll Compressor
Power KW 1.7 2.25 2.5 3 3.75 4.5 3.75+2.2 3.75+2.2 3.75*2 4.5*2 3.75*3 4.5*3 3.75*4 9*2 9*2+3.75 9*3
Noise Level dB(A) 48 50 50 51 52 52 53 53 55 56 58 60 62 65 68 68
Weight kg 310 370 390 550 590 650 780 820 890 920 980 1180 1480 1550 1780 1920
                                     
Note:1.Nominal cooling condition: indoor discharge air:DB27ºC/WB19.5ºC,outdoor fresh air: DB34ºC/WB28ºC.                   
           2.Nominal heating condition: indoor discharge air:DB21ºC/WB15ºC,outdoor fresh air: DB7ºC/WB6ºC.                                              
           3. Ambient  temperature conditions:-15ºC~43ºC                
          4. The specifications are subject to change without notice for improvement                
Model Number HAXC010 HAXC015 HAXC020 HAXC025 HAXC030 HAXC040 HAXC050 HAXC060 HAXC080 HAXC100 HAXC120 HAXC160 HAXC200
Cooling Capacity KW 8.8 11.5 15.5 22 26.5 34 44 53 66 78 108 155 216
Heating Capacity KW 9.3 12.1 16 23 27.5 35.5 46 55 69 81 112 160 224
Voltage 220V~50HZ 380V/3PH~50HZ
Refrigerant R22/R407C
Fresh Air System Air Flow m³/h 1000 1500 2000 2500 3000 4000 5000 6000 8000 10000 12000 16000 20000
External Static Pressure Pa 80 100 120 120 180 180 220 240 250 300 350 420 480
Motor Power KW 0.2 0.3 0.55 0.55 0.75 1.1 1.1 1.5 2.2 3 4 4 5.5
Exhaust Air System Air Flow m³/h 1800 2800 3500 4500 5500 7000 8500 10000 13000 16000 20000 28000 33000
External Static Pressure Pa 100 120 150 150 180 220 240 250 300 350 400 450 550
Motor Power KW 0.55 0.75 1.1 1.1 1.5 2.2 2.2 3 4 4 7.5 11 15
Humidifying System (Optional) Type Wet Film Humidifier
Humidifying kg/h 3 5 5 8 8 10 10 15 15 20 20 25 25
Size mm DN16 DN20 DN25
Heat Exchange Efficiency >85%
Compressor Type   Rotor Type  Hermetic  Scroll 
Power KW 1.7 2.25 2.5 3.75 4.5 3.75+2.25 3.75*2 4.5*2 3.75*3 4.5*3 9*2 9*3 9*4
Noise Level dB(A) 48 50 50 5.1 52 52 53 53 56 58 60 65 68
Weight kg 300 370 390 520 570 630 780 870 920 980 1150 1450 1650
                               
Note:1.Rated cooling condition: indoor discharge air:DB27ºC/WB19.5ºC,outdoor fresh air: DB34ºC/WB28ºC.             
            2.Rated heating condition: indoor discharge air:DB21ºC/WB15ºC,outdoor fresh air: DB7ºC/WB6ºC.                                        
            3. Work environment temperature:-15ºC~43ºC.          
           4.In winter, user may use an auxiliary heater and fresh air pre-heater (must be used in case of below -5ºC ambient temperature). Heating type: electric heating, hot water coil or steam coil heating.
           5.The humidifying system is optional.


3) Display:

Smaller Sizes Type Heat Recovery Fresh Air Handling Unit

4) Packing
Smaller Sizes Type Heat Recovery Fresh Air Handling Unit

5) Our company file
Smaller Sizes Type Heat Recovery Fresh Air Handling Unit


6) Contact Way
Person: Angie Pan
Mobile: +86 13630004922
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier