1)The Feature of 28kw operating room dx fresh air handling unit
The HAC and HWC series of air or water cooled cleaning air conditioners that we develop are able to perform air purification based on original funtion of accurate regulation of air temperature so as to achiese high effciency and enhance the external static pressure, suitable for user to directly use high-effcient filter.
Therefore, this products is applicable for such fields as medical and health,bio-engineering, food and beverage, electronics, instrumentaion,precise machinery,aerospace and other places wheregive strict requirements on air temperature,humidity and cleanliness.
HWC wate cooled units are applicable for the regions where enjoy sufficient water and allow for the erection of cooling water tower.
HAC air cooled units are applicable for the regions where is short of water of not suitable for the erection of cooling water tower.
HAC and HWC series of units can be attached with exclusive heat collector,saving electricity over 30%.
Exclusive remoter controller can be used,with maximum distance up to 800m.
2)Product model
|
Parameter |
Model |
HAC03(D) |
HAC05(D) |
HAC08(D) |
HAC10(D) |
HAC13(D) |
HAC15(D) |
HAC20(D) |
HAC25(D) |
HAC30(D) |
HAC40(D) |
HAC50(D) |
HAC60(D) |
HAC80(D) |
Item |
performance |
Cooling capacity |
KW |
7.8 |
13.0 |
20.8 |
26.0 |
33.8 |
39.0 |
52.0 |
65.0 |
78.0 |
104.0 |
130.0 |
156.0 |
208.0 |
Heating capacity |
KW |
8.1 |
13.6 |
22.1 |
27.5 |
35.6 |
41.5 |
56.8 |
69 |
82 |
110 |
136 |
162 |
216 |
Electric heating capacity |
KW |
6 |
9 |
13.6 |
18 |
24 |
24 |
36 |
45 |
48 |
54 |
72 |
90 |
108 |
Air flow |
m3/h |
1700 |
2600 |
4000 |
5400 |
7000 |
8000 |
10500 |
13500 |
18000 |
20500 |
25500 |
28000 |
36000 |
ESP(PA) |
Pa |
100 |
700 |
100 |
700 |
200 |
800 |
200 |
850 |
250 |
800 |
250 |
850 |
2500 |
850 |
300 |
900 |
300 |
900 |
350 |
950 |
350 |
950 |
400 |
1000 |
400 |
1000 |
Noise |
dB(A) |
57 |
71 |
63 |
73 |
65 |
74 |
66 |
75 |
67 |
75 |
67 |
75 |
70 |
77 |
69 |
77 |
71 |
79 |
71 |
79 |
72 |
79 |
74 |
81 |
75 |
82 |
Filter section |
F8(90~95%) |
Control Temp accurancy |
18~30ºC±2ºC |
Power supply |
3N~50HZ 380V |
Power input |
KW |
3.4 |
4.5 |
4.5 |
6.2 |
8.5 |
10.0 |
10.3 |
12.1 |
12.8 |
15.3 |
15.0 |
17.5 |
20.2 |
23.7 |
25 |
30.5 |
29.3 |
34.3 |
41 |
48.0 |
50 |
61 |
63 |
70 |
81.0 |
96 |
Refrigerant |
Name |
R22/R407,R410 etc |
Expansion way |
expansion valve |
Charge Volume |
kg |
3.1 |
4.0 |
4.0+3.1 |
4.0×2 |
4.6×2 |
4.3×3 |
7.0×2 |
7.5×2 |
7.5×2+4.0 |
7.5×3+4.0 |
7.5×4 |
7.5×5 |
68 |
Compressor |
Type |
flexible hermetic scroll compressor |
Semi-hermetic screw |
Power |
KW |
2.7 |
3.75 |
3.75+2.7 |
3.75×2 |
4.5×2 |
3.75×3 |
7.5×2 |
9×2 |
9×2+3.75 |
9×3+3.75 |
9×4 |
9×5 |
60 |
Indoor unt |
Evaporator |
Type |
tube with fin |
Fin type |
Slotted-type two-way aluminum fin / honeycomb type aluminum fin |
Fan |
Type |
ultra-low noise axial type |
Driving method |
Belt driven |
Motor power |
KW |
0.55 |
1.5 |
0.55 |
2.2 |
1.5 |
3 |
2.2 |
4 |
3 |
5.5 |
3 |
5.5 |
4 |
7.5 |
5.5 |
11 |
3×2 |
5.5×2 |
4×2 |
7.5×2 |
5.5×2 |
11×2 |
7.5×2 |
11×2 |
7.5×2 |
15×2 |
Air filter |
Pre filter+Medium filter+high efficiency filter |
Weight |
kg |
130 |
180 |
250 |
300 |
420 |
520 |
650 |
750 |
850 |
1080 |
1380 |
1550 |
1800 |
|
|
|
Model |
HAC03(D) |
HAC05(D) |
HAC08(D) |
HAC10(D) |
HAC13(D) |
HAC15(D) |
HAC20(D) |
HWC25(D) |
HWC30(D) |
HWC40(D) |
HWC50(D) |
HWC60(D) |
HWC80 (D) |
Item |
Parameter |
|
performance |
Cooling capacity |
KW |
7.8 |
13.0 |
20.8 |
26.0 |
33.8 |
39.0 |
52.0 |
75.0 |
90.0 |
120.0 |
150.0 |
180.0 |
240.0 |
Air flow |
m3/h |
1700 |
2600 |
4000 |
5400 |
7000 |
8000 |
10500 |
13500 |
18000 |
20500 |
25500 |
28000 |
36000 |
ESP(PA) |
Pa |
100 |
700 |
100 |
700 |
200 |
800 |
200 |
850 |
250 |
800 |
250 |
850 |
2500 |
850 |
300 |
900 |
300 |
900 |
350 |
950 |
350 |
950 |
400 |
1000 |
400 |
1000 |
Noise |
dB(A) |
57 |
71 |
63 |
73 |
65 |
74 |
66 |
75 |
67 |
75 |
67 |
75 |
70 |
77 |
70 |
78 |
72 |
80 |
72 |
80 |
73 |
80 |
75 |
82 |
75 |
83 |
Filter section |
F8(90~95%) |
Control Temp accurancy |
18~30ºC±2ºC |
Power supply |
3N~50HZ 380V |
Power input |
KW |
3.4 |
4.5 |
4.5 |
6.2 |
8.5 |
10.0 |
10.3 |
12.1 |
12.8 |
15.3 |
15.0 |
17.5 |
20.2 |
23.7 |
23.5 |
29.0 |
27.8 |
32.7 |
38.75 |
45.75 |
47.0 |
58.0 |
60.0 |
67.0 |
75.0 |
90.0 |
Refrigerant |
Name |
R22/R407,R410 etc |
Expansion way |
expansion valve |
expansion valve |
Charge Volume |
kg |
3.1 |
4.0 |
4.0+3.1 |
4.0×2 |
4.6×2 |
4.3×3 |
7.0×2 |
7×2 |
7×2+3.5 |
7×3+3.5 |
7×4 |
7×5 |
42 |
Compressor |
Type |
flexible hermetic scroll compressor |
Semi-hermetic screw |
Power |
KW |
2.7 |
3.75 |
3.75+2.7 |
3.75×2 |
4.5×2 |
3.75×3 |
7.5×2 |
9×2 |
9×2+3.75 |
9×3+3.75 |
9×4 |
9×5 |
60 |
Indoor unit |
Evaporator |
Type |
tube with fin |
Fin type |
Slotted-type two-way aluminum fin / honeycomb type aluminum fin |
Fan |
Type |
ultra-low noise axial type |
Driving method |
Belt driven |
Motor power |
KW |
0.55 |
1.5 |
0.55 |
2.2 |
1.5 |
3 |
2.2 |
4 |
3 |
5.5 |
3 |
5.5 |
4 |
7.5 |
5.5 |
11 |
3×2 |
5.5×2 |
4×2 |
7.5×2 |
5.5×2 |
11×2 |
7.5×2 |
11×2 |
7.5×2 |
15×2 |
Air filter |
Pre filter+Medium filter+high efficiency filter |
Pre filter+Medium filter+high efficiency filter |
Weight |
kg |
130 |
180 |
250 |
300 |
420 |
520 |
650 |
1460 |
1580 |
2020 |
2300 |
2680 |
2980 |
3) Display:
4)Packing
5)Our company file