45kw Heat Recovery Fresh Air Handling Unit Ahu

Product Details
Customization: Available
Type: Heat Recovery Unit
Air Tube Material: Customized
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2011

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
76
Year of Establishment
2004-12-28
  • 45kw Heat Recovery Fresh Air Handling Unit Ahu
  • 45kw Heat Recovery Fresh Air Handling Unit Ahu
  • 45kw Heat Recovery Fresh Air Handling Unit Ahu
  • 45kw Heat Recovery Fresh Air Handling Unit Ahu
  • 45kw Heat Recovery Fresh Air Handling Unit Ahu
  • 45kw Heat Recovery Fresh Air Handling Unit Ahu
Find Similar Products

Basic Info.

Model NO.
HAX/HAXC/HWX/HWXC
Operating Voltage
380/400 VAC
Noise Level
Ultra Low
Application Fields
Airports, Stations, Exhibition Halls, Stadiums
Mounting
Ceiling Mount
Lifetime
10~15 years
Certification
ISO, CE, Soncap
Condition
New
Name
Heat Recovery Fresh Air Unit with Heat Pump Air FL
Cooling Capacity
9-167kw
Refrigerant
R22/R407cr410A etc
Transport Package
Plastc+Foam+Woden Case
Specification
800-2360kgs
Trademark
Headpower
Origin
China(Mainland)
Production Capacity
500 Units/Month

Product Description

Guangdong Head-Power Air Conditioning is a modernized professional enerprise engaging in the manufacture of cental air conditioners. Since we founded in 2001, based on social development needs , we are committed to upgrade of technological innovation, continuously forge ahead and create new brilliance. We has rich experience in design and manufacturing of refrigeration dehumidifiers.
All products have passed ISO 9001 Certificate and ISO 14001 Certificate, some  equipments have CE Certificate and CCS Certificate as well. Meanwhile, our company have a number of invention patents (Patent NO.: ZL200910246621.7,  ZL200910246620.2)  and utility model patents (Patent NO.: ZL201120547872.1, ZL201220043474.0, ZL201220124504.0, ZL2009920273841.4 and ZL200920273842.9), and participate in setting HVAC industry standards. Head-Power is also the secretariat of Guangdong HVAC and Purification Equipment Standardization Technical Committee.

Description:

1. Double skin galvanized steel sheet, aluminium alloy frame, 30mm thick PU insulation.  
2. This heat recovery unit  is mainly used for heat recovery and ventilation, combined with supply fan and motor, exhaust fan and motor, heat recovery wheel and filters.
3. Energy saving and improve indoor air quality: this fresh air unit can not only introduce fresh air to                improve indoor air quality, at the same time, it exchanges heat with exhaust air, which can precool for preheat fresh air, save much energy.
4. Cooling coil or heating coil is optional at supply air section to be heat recovery AHU. 
5. Silica-gel heat recovery wheel, full heat recovery, high efficiency up to 80%. 
6. Washable nylon prefilter or plate filter G4 is installed at air intake. Bag filter is optional.
7. Air volume: 1000 m3/h ~20000 m3/h. 
8. Standard power supply: 380~415V/3PH/50Hz.

 Advantages:
 
1. Heat and energy heat recovery, saving energy for building consumption. 
2. Introduce fresh air, exhaust polluted air, improvde indoor air quality;
3. Wide volume range, meet different requirements of industrial, commercial and residential building;
4. Good quality heat exchange device, high efficiency and long lifespan. 
5. Easy for maintainance and operation, low cost. 
 
Heat Recovery Fresh Air Handling Unit
Model No.   HAXC010 HAXC015 HAXC020 HAXC025
Quantity unit 1 1 1 1
Nominal cooling capacity kw 8.8 11.5 15.5 22
Nominal heating capacity kw 9.3 12.1 16 23
Power supply   380V/3PH/50Hz
Refrigerant   R22/R410A/R407C
Compressor Type   Hermetic Scroll
Power kw 1.7 2.25 2.5 3.75
Exhaust air system Air volume m3/h 1800 2800 3500 4500
CFM 1059 1647 2059 2647
ESP. Pa 100 120 150 150
Motor power kw 0.55 0.75 1.1 1.1
Fresh air system Air volume m3/h 1000 1500 2000 2500
CFM 588 882 1176 1471
ESP. Pa 80 100 120 120
Motor power kw 0.2 0.3 0.55 0.55
Heat exchange efficiency   >85%
Noise level dB(A) 48 50 50 51
Net weight kg 300 370 390 520
             
Note:            
1.Cooling conditions:indoor exhaust air DB27ºC/WB19ºC,outdoor fresh air DB34/WB28ºC.  
2.Heating conditions:indoor exhaust air DB21ºC/WB15ºC,outdoor fresh air DB7/WB6ºC.    
3.Environment working temperature range:-15~43ºC.      
4. In winter, user may use an auxiliary heater and fresh air preheater must be used when ambient air temperature below -5ºC. 
45kw Heat Recovery Fresh Air Handling Unit Ahu
45kw Heat Recovery Fresh Air Handling Unit Ahu
45kw Heat Recovery Fresh Air Handling Unit Ahu
45kw Heat Recovery Fresh Air Handling Unit Ahu
45kw Heat Recovery Fresh Air Handling Unit Ahu
45kw Heat Recovery Fresh Air Handling Unit Ahu


 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier