10 Ton Double Skin Chilled Water Air Handling Unit

Product Details
Customization: Available
Type: Air Handling Unit
Air Tube Material: Galvanized Sheet
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2011

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
76
Year of Establishment
2004-12-28
Find Similar Products

Basic Info.

Model NO.
PWB
Operating Voltage
220V,380V,160V,440V etc.
Noise Level
Ultra Low
Application Fields
Air Conditioning
Mounting
Floor/Ceiling
Lifetime
>20 years
Certification
ISO, CE
Condition
New
Name
10 Ton Double Skin Chilled Water Ahu Ventilation
Air Floe
1500-60000 CMH
Total Cooling Capacity
9.62-466.28kw
Sensible Cooling Capacity
6.75-293.76kw
Heating Capacity
16.06-638.86kw
Esp
110-550 PA
Motor Power
0.55-11*2kw
Transport Package
Plastc+Foam+Woden Case
Specification
1unit/case
Trademark
Headpower
Origin
Guangdong Foshan
Production Capacity
500 Units/Months

Product Description

1)The Feature of 10 ton double skin Chilled water ahu ventilation air handling unit 
a.Frame structure
The latest reinforced aluminum alloy profile is used, with surface being subject to andoic oxidation treatment and internal foamed, to prevent the sweat phenomenon on the frame surface,being  firm and beautiful.
b.Box board
It's of sandwich board structure,with foam insulation, of standard thickness 25mm,in which the external material is the second sprayed dhot-dip galvanized sheet steel, of beautiful appearance,resistant to corrosion,rust and weathering;the inner plate is hot-dip galvanized sheet, also resistant to corrosion and rust;the middle rigid polyuredthane foam is uniformly mixed, providing closely integration of external and internal panels and excellent thermal insulation.The box board enjoys firm structure and has excellent performance against sound and vibration.
c.Structure of heat exchange oil
The heat exchange tube are arranged in the triangular staggered manner,generally48 rows;the heat exchanges tubes are made of high-quality copper(TP2).
The High-efficient heat exchanger is made on U.S.OAK assembly line. After overall passing through,the copper tube is closely integrated with the aluminum pieces,providing excellent heat transfer effect,satifsfactory for the occasions of the thermal performance requirements;precision processiong machinery and strict processing control ensure uniform piece distance and tight tube expansion.
The external frame of the coil is bent formed with galvanized stell sheet, being firm and durable;bolt connections are used to prevent rust duce to welding of the galvanized layer.
The design work pressure of the coil is 16 bars,test pressure 25 bars.
e.Fans and motors
Double air-intake centrifugal efficient fans are used, including a volute made of high-quality galvanized steel plate;the side plate enjoys elaborately designed streamlined appearance and machining air intake;the side plate is manufactured with one stamping,enjoying high stiffness,not liable to fatigue dampage;the external part of big fan is a fixed frame structure,enjoying high strngth,stable operation and low vibration;fan impellers are made of high-quality steel plate, of particular streamline shape;each impeller has passed the internal control static/dynamic balance inspection according to national standards.
Fan bearings are from international famous brands,are air-tight ball bearings ,being prior lubricated and aligned,needing no mainTENANCE DURING NORMAL USE  PERIOD.
Fan shafts are made of C-45 steel,being subject to rough processing, finishing,secondary quenching and tempering,and will not rust ,easy for repair and maintenance.
Generally low speed fans are used in order to minimize the noise and vibration on the premise that the requirements of  air quaitity and pressure are met.
Fan  motos are provided by renowed manufacturers,with insulation class B so as to ensure the quality and service life;in addition, the motors of given bradns can be provided when user requires so,or motor insulation class can be enhanced in order to meet the needs of different occasions.
The fans are driven by belts,i.e high-quality V-shaped belits;belt pulleys are precisely machined to ensure concentricity and in accurate matching of the belt;after fans and motors assembly, the second running dynamic balance inspection is carried out in order to achieve the minumum vibration and the highest transmission efficiency.
The bases of fans and notors are all equipped with suitable damper spring shock absorbers;fan outlets and outside box are all flexibly connected using anti-corrosive and moisture-resistant canvas.
f.Coil design
According to varied flows, temperature differences and operating conditions,different internal process designs are adopted in order to maintain coil heat exchange performance and coil water pressure drop at a reasonable and efficient levels and reduce applicaiton difficulty;designed head-on wind speed is 2.5m/s-2.8m/s,and special design requirements are also acceptable
g.Filters
Double nylon embossed nets are used,easy for replacement and removal,can be cleaned and used repeatedly.Non-wovem plate filter can also be fitted at the air intake when required, or a new fresh return air mixing box be used.
Large dust capacity:under the designed final resistance(double the initial resistance)the dust capacity per square meter is more than 100g.
2)Product model
Return Air Condition Items DB. Temp. WB. Temp. Inlet Water Temp. Water Temp. Difference
Nominal Cooling Condition 27.0ºC 19.5ºC 7.0ºC 5.0ºC
Nominal Heating Condition 21.0ºC   60.0ºC  
Super-thin Ceiling Mounted Unit
Model Type Air flow Noise Level Cooling Capacity Heating Capacity External Static Pressure Motor Power Water Flow Water Resistence Unit Weight 
m3/h dB(A) Total Heat Sensible Heat
KW KW Pa KW kg/h kPa kg
PWB 40-4H 4000 ≤58 24.68 17.27 41.8 140 1.1 4245 9.5 250
40-6H 31.38 20.86 43.55 130 5397 16.5 268
45-4H 4500 ≤58 27.96 20.81 47.33 150 1.1 4809 10.5 265
45-6H 35.42 22.76 49.64 140 6092 17.8 276
50-4H 5000 ≤58 31.29 22.37 52.33 150 1.1 5382 12.3 292
50-6H 39.11 26.28 55.74 140 6727 19.7 310
55-4H 5500 ≤59 33.67 25.08 56.17 150 1.1 5791 14.7 307
55-6H 43.85 28.97 61.09 140 7542 21.4 325
60-4H 6000 ≤60 36.37 26.17 60.68 200 1.5 6256 17.6 338
60-6H 47.53 31.28 64.58 190 8175 24.1 356
65-4H 6500 ≤60 39.54 28.63 65.69 210 1.5 6800 19.5 355
65-6H 52.73 33.81 71.65 200 9069 27.5 371
70-4H 7000 ≤60 43.26 30.96 72.34 220 1.5 7440 21.8 355
70-6H 57.35 36.55 76.34 210 9664 30.9 376
80-4H 8000 ≤62 53.39 36.73 88.07 230 2.2 9183 24.2 379
80-6H 68.10 43.59 91.36 220 11713 34.8 405
90-4H 9000 ≤62 57.24 41.57 94.52 230 2 9845 26.7 411
90-6H 73.84 47.51 99.06 220 12700 36.4 435
100-4H 10000 ≤63 60.67 43.38 101.22 230 3 10435 27.4 456
100-6H 78.73 50.92 108.33 220 13541 37.9 495
110-4H 11000 ≤64 67.06 48.38 111.88 240 3 11534 28.8 476
110-6H 86.77 56.64 119.39 230 14924 38.4 520
120-4H 12000 ≤65 72.28 52.31 120.45 290 3 12432 29.6 490
120-6H 94.63 61.17 128.54 280 16276 39.7 530
130-4H 13000 ≤65 78.65 55.89 131.57 300 4 13528 30.4 500
130-6H 101.47 65.47 139.76 290 17452 41.1 554
140-4H 14000 ≤66 84.47 60.90 142.37 290 4 14528 31.0 513
140-6H 109.19 70.86 150.30 280 18781 40.6 560
150-4H 15000 ≤66 92.73 64.61 156.19 310 5.5 15950 33.5 530
150-6H 118.85 78.24 161.24 300 20442 41.4 581
160-4H 16000 ≤66 98.68 69.88 167.76 300 5.5 16973 36.7 540
160-6H 128.10 81.75 170.55 290 22033 42.3 590
Return Air Condition Items DB. Temp. WB. Temp. Inlet Water Temp. Water Temp. Difference
Nominal Cooling Condition 27.0ºC 19.5ºC 7.0ºC 5.0ºC
Nominal Heating Condition 21.0ºC   60.0ºC  
Ceiling Mounted Unit
Model Type Air Flow Noise Level Cooling Capacity Heating Capacity External Static Pressure Motor Power Water Flow Water Resistence Unit Weight 
Model Type dB(A) Total Heat Sensible Heat
KW KW Pa KW kg/h kPa kg
PWD 15-4H 1500 ≤52 9.62 6.75 16.06 110 0.55 1655 4.4 125
15-6H 12.72 8.90 21.21 100 2187 5.6 130
20-4H 2000 ≤52 12.65 8.83 20.93 110 0.55 2176 5.2 150
20-6H 16.02 10.38 21.95 100 2755 7.2 158
25-4H 2500 ≤53 15.72 10.98 26.05 120 0.55 2703 5.9 170
25-6H 19.86 12.64 27.26 110 3416 8.0 180
30-4H 3000 ≤56 19.08 13.38 32.27 140 0.75 3281 6.7 195
30-6H 24.03 15.38 33.69 130 4133 10.4 210
35-4H 3500 ≤56 21.31 15.43 36.82 160 0.75 3665 7.8 235
35-6H 27.03 17.95 38.67 150 4649 13.0 250
40-4H 4000 ≤58 24.68 17.27 41.80 160 1.1 4245 9.5 254
40-6H 31.38 20.86 43.55 150 5397 16.5 270
45-4H 4500 ≤58 27.98 20.81 47.33 210 1.1 4809 10.5 268
45-6H 35.42 22.76 49.64 200 6092 17.8 280
50-4H 5000 ≤58 31.29 22.37 52.33 210 1.1 5382 9.1 295
50-6H 39.11 26.28 55.74 200 6727 15.7 312
55-4H 5500 ≤59 33.67 25.08 56.17 220 1.1 5791 9.8 310
55-6H 43.85 28.97 61.09 210 7542 17.3 327
60-4H 6000 ≤60 36.37 26.17 60.68 230 1.5 6256 10.9 341
60-6H 47.53 31.28 64.58 220 8175 19.2 260
65-4H 6500 ≤60 39.54 28.63 65.96 230 1.5 6800 11.7 358
65-6H 52.73 33.81 71.65 220 9069 21.0 375
70-4H 7000 ≤60 43.26 30.96 72.17 270 1.5 7440 12.9 360
70-6H 57.35 36.55 76.34 230 9664 23.2 380
80-4H 8000 ≤62 53.39 36.73 88.07 250 2.2 9183 14.3 382
80-6H 68.10 43.59 91.36 240 11713 25.9 408
90-4H 9000 ≤62 57.24 41.47 94.52 280 2.2 9845 22.6 415
90-6H 73.84 47.51 99.06 270 12700 20.5 440
100-4H 10000 ≤63 60.67 43.36 101.22 280 3 10435 12.8 460
100-6H 78.73 50.92 108.33 270 13541 22.9 500
110-4H 11000 ≤64 67.06 48.38 111.88 310 3 11535 13.8 480
110-6H 86.77 56.64 119.39 300 14924 24.9 524
120-4H 12000 ≤65 72.28 52.31 120.45 290 3 12432 14.4 495
120-6H 94.63 61.17 128.54 280 16276 25.8 535
130-4H 13000 ≤65 78.65 55.89 131.57 300 4 13528 19.6 510
130-6H 101.47 65.47 139.76 290 17452 27.3 558
140-4H 14000 ≤66 84.47 60.90 142.37 300 4 14528 26.3 520
140-6H 109.19 70.86 150.30 290 18781 20.9 570
150-4H 15000 ≤66 92.73 64.61 156.19 310 5.5 15950 28.7 535
150-6H 118.85 78.24 161.24 300 20442 22.1 589
160-4H 16000 ≤66 98.68 69.88 167.76 310 5.5 16973 30.8 546
160-6H 128.10 84.75 170.55 300 22033 24.5 600
Return Air Condition Items DB. Temp. WB. Temp. Inlet Water Temp. Water Temp. Difference
Nominal Cooling Condition 27.0ºC 19.5ºC 7.0ºC 5.0ºC
Nominal Heating Condition 21.0ºC   60.0ºC  
floor standing unit
Model Type Air Flow Noise Level Cooling Capacity Heating Capacity External Static Pressure Motor Power Water Flow Water Resistence Unit Weight 
Model Type dB(A) Total Heat Sensible Heat
KW KW Pa KW kg/h kPa kg
PWL 40-4H 4000 ≤58 24.68 17.27 41.80 170 1.1 4245 6.7 256
40-6H 31.38 20.86 43.55 160 5397 10.3 276
45-4H 4500 ≤58 27.96 20.81 47.33 200 1.1 4809 7.6 275
45-6H 35.42 22.76 49.64 190 6092 12.1 286
50-4H 5000 ≤58 31.29 22.37 52.33 200 1.1 5282 8.5 302
50-6H 39.11 26.28 55.74 190 6727 13.9 319
55-4H 5500 ≤59 33.67 25.08 56.17 210 1.1 5791 9.5 318
55-6H 43.85 28.97 61.09 200 7542 15.7 335
60-4H 6000 ≤60 36.37 26.17 60.68 230 1.5 6256 10.6 350
60-6H 47.53 31.28 64.58 220 8175 17.8 370
65-4H 6500 ≤60 39.54 28.63 65.69 230 1.5 6800 11.7 371
65-6H 52.73 33.81 71.65 220 9069 19.5 387
70-4H 7000 ≤60 43.26 30.96 72.17 300 1.5 7440 12.5 372
70-6H 57.35 36.55 76.34 290 9664 21.3 393
80-4H 8000 ≤60 53.39 36.73 88.07 300 2.2 9183 13.4 394
80-6H 68.10 43.59 91.36 290 11713 23.9 420
90-4H 9000 ≤62 57.24 41.47 94.52 310 2.2 9845 14.4 427
90-6H 73.84 47.51 99.06 300 12700 25.7 455
100-4H 10000 ≤63 60.67 43.36 101.22 310 3 10435 27.4 476
100-6H 78.73 50.92 108.33 300 13541 16.4 517
110-4H 11000 ≤64 67.06 48.38 111.88 310 3 11543 16.5 498
110-6H 86.77 56.64 119.39 300 14924 30.8 540
120-4H 12000 ≤65 73.39 53.04 122.44 350 3 12623 17.3 510
120-6H 94.28 62.31 129.70 340 16216 31.3 554
130-4H 13000 ≤65 78.65 55.89 131.57 350 4 13528 17.6 518
130-6H 101.47 65.47 139.76 340 17452 32.4 564
140-4H 14000 ≤66 84.47 60.90 142.37 360 4 14528 18.1 535
140-6H 109.19 70.86 150.30 350 18781 33.8 586
150-4H 15000 ≤66 92.73 64.61 156.19 360 5.5 15950 18.8 546
150-6H 118.85 78.24 161.24 360 20442 35.2 601
160-4H 16000 ≤66 98.68 69.88 167.76 350 5.5 16973 19.4 560
160-6H 128.10 81.75 170.55 360 22033 36.7 620
180-4H 18000 ≤66 119.58 82.03 194.49 350 5.5 20567 26.5 603
180-6H 154.44 96.92 212.51 340 26564 40.8 662
200-4H 20000 ≤67 130.50 89.63 215.72 360 5.5 22446 31.3 652
200-6H 170.95 108.08 234.63 350 29403 47.5 715
Return Air Condition Items DB. Temp. WB. Temp. Inlet Water Temp. Water Temp. Difference
Nominal Cooling Condition 27.0ºC 19.5ºC 7.0ºC 5.0ºC
Nominal Heating Condition 21.0ºC   60.0ºC  
floor standing unit
Model Type Air Flow Noise Level Cooling Capacity Heating Capacity External Static Pressure Motor Power Water Flow Water Resistence Unit Weight 
Model Type dB(A) Total Heat Sensible Heat
KW KW Pa KW kg/h kPa kg
PWL 220-4H 22000 ≤68 142.35 99.49 230.45 360 5.5 24484 16.5 803
220-6H 183.47 116.78 264.01 350 31557 30.8 887
250-4H 25000 ≤69 160.87 111.57 268.39 350 7.5 27670 17.3 854
250-6H 206.48 130.31 284.15 340 35514 31.3 945
280-4H 28000 ≤70 176.22 123.21 293.67 350 7.5 30310 17.9 935
280-6H 227.34 143.62 311.54 340 39102 32.0 1050
300-4H 30000 ≤71 190.13 130.29 317.21 350 7.5 32703 18.4 1025
300-6H 245.36 158.73 336.72 340 42201 32.8 1130
350-4H 35000 ≤73 218.01 154.43 363.38 450 5.5×2 37497 18.1 1080
350-6H 298.38 185.60 385.31 440 51321 33.4 1250
400-4H 40000 ≤74 250.35 178.52 421.54 460 5.5×2 43060 31.3 1183
400-6H 347.66 220.75 446.17 450 59798 47.5 1340
450-4H 45000 ≤74 286.37 200.83 473.56 480 7.5×2 49255 27.4 1270
450-6H 383.48 2422.67 497.23 470 65959 42.5 1490
500-4H 50000 ≤74 320.48 224.33 528.44 500 7.5×2 55122 24.3 1410
500-6H 418.61 263.72 551.57 490 72001 376 1620
600-4H 60000 ≤75 382.56 266.79 603.75 560 11×2 65800 27.7 1650
600-6H 466.28 293.76 638.86 550 80200 39.4 1845
3) Display:

10 Ton Double Skin Chilled Water Air Handling Unit
4)Packing
10 Ton Double Skin Chilled Water Air Handling Unit
5)Our company file
10 Ton Double Skin Chilled Water Air Handling Unit


5)Company Culture:

Serve the society with technology, serve the customer with    heart, become a  first level air conditioning company in China.
Innovation, loyalty, responsibility, value.
Provide customer with high quality product and considerable service.

6)Our services:

1) Changing on material, color, shape, construction:Acceptable.
2) General inspection on fixing before packing
4) We can offer you premium quality , competitive price, prompt delivery and low minimum orders.
5) OEM,ODM service.

7)Project and client:

No

Project Name ( China)

Industry

Area

1

Zhongshan people hospital

Hospital

Zhongshan

2

Hankou Railway Station, Union Hospital, Wuhan Branch

Hospital

Wuhan

3

Wuhan City, Wuchang Railway Hospital

Hospital

Wuhan

4

Three townships Zhongshan People's Hospital

Hospital

Zhongshan

5

Zhujiang hospital of Guangzhou

Hospital

Guangzhou

6

Zhongshan Garden Hotel

Hotel   industry

Zhongshan

7

Western Sunshine Hotel, Zhongshan

Hotel   industry

Zhongshan

8

Shunde Golden Hotel

Hotel   industry

Foshan

9

East China Hotel in Guangzhou

Hotel   industry

Guangzhou

10

Nanyou Zhuhai hotel

Hotel   industry

Zhuhai

No

Company Name ( Overseas)

Product

Country

1

SB Global Energy

Air cooled ducted split

Holland

2

Bentos pharmaceutical products Ltd.

Clean air conditioners

Nigeria

3

SOGAMEF

Air cooled chiller

Gabon

4

SeaService shipping

Marine air conditioner

Russia

5

EURO STANDARD LIMITED

Fresh Air Handling Unit

New Zealand

6

Henrich trading center

Air cooled/water cooled air conditioner

Philippines

7

Marine Engineering Systems Pte.Ltd

AHU, chiller,etc

Singapore

8

Elektro Werner Heitzinger

Heat recovery air handling unit

Austria

9

Nyborg Marine Equipments AS

Marine Air Handling Units

Norway

10

Wilfred Limited

Heat recovery air handling unit

UK
 

Contact Way:
Carrie Mak
GuangDong Head-Power Air Conditioning Co.,Ltd.
Add: Shiling Chenbian Section, 321 National Highway, Shishan Town,
Nanhai District, Foshan,Guangdong,China.
Mobile:86-15024293999
Tel: 86-757-88364517,18 Fax:86-757-86688063
 
http://headpower2.en.made-in-china.com

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now