300kw Ground Source Heat Pump Water Chiller Unit

Product Details
Customization: Available
Type: Water-Cooled
Cooling Method: Water-cooled
Still deciding? Get samples of US$ 5000/Piece
Request Sample
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2011

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
76
Year of Establishment
2004-12-28
  • 300kw Ground Source Heat Pump Water Chiller Unit
  • 300kw Ground Source Heat Pump Water Chiller Unit
  • 300kw Ground Source Heat Pump Water Chiller Unit
  • 300kw Ground Source Heat Pump Water Chiller Unit
  • 300kw Ground Source Heat Pump Water Chiller Unit
Find Similar Products

Basic Info.

Model NO.
HWWL
Unit Structure
Integral
Selected Voltage
380V/50HZ
Compressor Number
2
Noise Level
Low
Application Fields
Electronic
Application Machine
Machining Center
Certification
ISO, CE
Condition
New
Refrigerant
R22/407c/R134A
Transport Package
Stretch Roll Film, EPE, Wooden Package
Specification
Customize
Trademark
Head-Power
Origin
China(Mainland)
Production Capacity
600 Sets/Month

Product Description

300KW Ground Source Heat Pump Water Chiller Unit
Specifications:
Cooling only type;
Screw compressor
Chilled outlet/inlet water temp. 7/12 degree.
Cooling capacity:150~1900kw.
R22/407c/410a
Features:
1. 300KW Ground Source Heat Pump Water Chiller Unit Superior Performance: international advanced semi-closed screw compressor; several  refrigerant circuits insure no stop when one circuit needs maintenance; low noise; efficient heat transfer;
2. Unique High Temperature Type Chiller
3.300KW Ground Source Heat Pump Water Chiller Unit Easy Installation: compact structure, take up limited space; refrigerant has been filled in the chiller so as to save time and expenses;
4. Low Cost for Operation and Maintenance;
5. Comprehensive Security Protection: high and low pressure protection, electric motor protection, safety valve protection, all the above protections ensure the 300KW Ground Source Heat Pump Water Chiller Unit unit safe and stable in operation.
6. Optional device: partial or total heat recovery system
7. Cooling capacity: 150~1900kw.
  
Condenser fan Model Ultra low-noise axial fan
  KW 1.1×4 1.1×5 1.1×6 1.1×8  1.1×10 1.1×12 1.1×16 1.1×12 1.1×16 1.1×20 1.1×24 1.1×32
     
    m3/h 26 32 43 56 67 86 102.5 85 111 135 172 223
  m3/h 28 33 44 58 69 87 103 86 113 136 172 223
  DN80 DN80 DN100 DN100 DN100 DN125 DN125 DN125 DN150 DN150 DN150 DN200
  KP 50~80
    KW 55 65 86 114 135 170 205 170 230 268 335 410
  m3/h 15.7 18.6 24.6 32.6 38.7 49 59 49 66 77 96 118
    KW 158 180 245 325 380 480 580 485 646 756 945 1160
  m3/h 45 52 90 93 109 138 166 139 185 217 270 320
  dB(A) 64 64 65 65 66 66 67 68 68 69 70 71
    m 2300 2500 3400 4400 5400 6400 7500 6400 8400 10500 6400/12500 7500/14500
  m 2200 2300 2300 2300 2300 2300 2300 2300 2300 2300 4200/2300 4200/2300
  m 2300 2350 2350 2350 2350 2350 2350 2350 2350 2350 2350 2350

product features
 Superior performance
Adopt world famous semi-hermetic screw compressor, integrate motors and compressors, no refrigerant leakage.
When there are several compressors, the control system will start and stop them by turns, balance the load of all components in order to prolong the life of unit .
The units always has several refrigerant circuits, when one of them needs maintenance, the rest can also work normally.
 The compressor adopts unloading and step-down voltage starting method to avoid the impact of power system.
Ultra-low noise design of turbine blades.
V-type structural design, good cooling effect.
Unique high-temperature-type unit
High-temperature heat pump unit can provide maximum 55-60 ºC hot water for heating, and also sanitary hot water. The idea of "big difference, small flow" is in line with energy saving which we always place at first place.
Easy installation
Compact structure,take up small area, save room space.
The machine has been filled with R22 refrigerant and lubricant when it is finished in the factory, so it reduces installation time and costs.
Little vibration, and the installation of vibration isolation is easy.
You just need to connect water pipes to the evaporator when in installation..
Low operation and maintenance costs
 The unit can realize intelligent control in accordance with load demand: four-step(100%, 75%, 50%, 25%) capacity adjustment are available, thus when the unit is working under partial loading conditions, it can save energy to a large extent.
The total parts of screw compressor has only 1/10 of reciprocating compressor, simple structure, less wearing parts, no inlet/oulet valves, so it has a very low failure rate.
The screw compressor can work up to 40,000 hours trouble-free .
Security measures
Pressure protection: high pressure and low pressure protection device.
Motor Protection: loss of voltage protection, lack of phase protection, reverse-phase protector, internal overheat protector.
Anti-frozen protection: When the chilled water temperature is too low, the unit will stop.
Safe valve protection: When the refrigerant pressure exceeds a certain value, the safe exhaust valve will automatically open.
All the above protection measures assure the unit safe and stable.
 

300kw Ground Source Heat Pump Water Chiller Unit
300kw Ground Source Heat Pump Water Chiller Unit
300kw Ground Source Heat Pump Water Chiller Unit
300kw Ground Source Heat Pump Water Chiller Unit
300kw Ground Source Heat Pump Water Chiller Unit
300kw Ground Source Heat Pump Water Chiller Unit

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier