Medical workshop air handling unit AHU
Guangdong Head-Power Air Conditioning is a modernized professional enerprise engaging in the manufacture of cental air conditioners. Since we founded in 2001, based on social development needs , we are committed to upgrade of technological innovation, continuously forge ahead and create new brilliance. We has rich experience in design and manufacturing of refrigeration dehumidifiers.
All products have passed ISO 9001 Certificate and ISO 14001 Certificate, some equipments have CE Certificate and CCS Certificate as well. Meanwhile, our company have a number of invention patents (Patent NO.: ZL200910246621.7, ZL200910246620.2) and utility model patents (Patent NO.: ZL201120547872.1, ZL201220043474.0, ZL201220124504.0, ZL2009920273841.4 and ZL200920273842.9), and participate in setting HVAC industry standards. Head-Power is also the secretariat of Guangdong HVAC and Purification Equipment Standardization Technical Committee.
Description:
1. Double skin galvanized steel sheet, aluminium alloy frame, 30mm thick PU insulation.
2. This heat recovery unit is mainly used for heat recovery and ventilation, combined with supply fan and motor, exhaust fan and motor, heat recovery wheel and filters.
3. Energy saving and improve indoor air quality: this fresh air unit can not only introduce fresh air to improve indoor air quality, at the same time, it exchanges heat with exhaust air, which can precool for preheat fresh air, save much energy.
4. Cooling coil or heating coil is optional at supply air section to be heat recovery AHU.
5. Silica-gel heat recovery wheel, full heat recovery, high efficiency up to 80%.
6. Washable nylon prefilter or plate filter G4 is installed at air intake. Bag filter is optional.
7. Air volume: 1000 m3/h ~20000 m3/h.
8. Standard power supply: 380~415V/3PH/50Hz.
Advantages:
1. Heat and energy heat recovery, saving energy for building consumption.
2. Introduce fresh air, exhaust polluted air, improvde indoor air quality;
3. Wide volume range, meet different requirements of industrial, commercial and residential building;
4. Good quality heat exchange device, high efficiency and long lifespan.
5. Easy for maintainance and operation, low cost.
Zk Series Assembly Air Handling Units |
Bitmap
|
|
|
Type |
ZK |
ZK |
ZK |
ZK |
ZK |
ZK |
ZK |
ZK |
ZK |
ZK |
ZK |
ZK |
ZK |
ZK |
Items |
|
|
6 |
8 |
10 |
15 |
20 |
25 |
30 |
40 |
50 |
60 |
80 |
100 |
120 |
140 |
Air Flow (m3/h) |
6000 |
8000 |
10000 |
15000 |
20000 |
25000 |
30000 |
40000 |
50000 |
60000 |
80000 |
100000 |
120000 |
140000 |
Section of Surface Cooling |
Windward Air Speed (m/s) |
≈2.5 |
Inlet/Outlet Water Temperature (ºC) |
7/12 |
Work Pressure (Mpa) |
1.6 |
Return Air Condition |
Inlet Air Temperature (ºC) |
DB27/WB19.5 |
4 Rows |
Cooling Capacity (KW) |
35.6 |
51.3 |
58.1 |
88.0 |
116.3 |
142.3 |
174.5 |
232.8 |
290.8 |
349.1 |
465.2 |
581.5 |
697.8 |
814.3 |
Water Flow (T/h) |
6.1 |
8.8 |
10.0 |
15.1 |
20.0 |
24.5 |
30.0 |
40.0 |
50.0 |
60.0 |
80.1 |
100.1 |
120.0 |
37.4 |
Water Resistance (Kpa) |
3.8 |
4.1 |
4.8 |
5.6 |
8.3 |
9.8 |
11.6 |
14.0 |
16.6 |
18.9 |
23.3 |
27.1 |
32.5 |
37.4 |
Air Resistance (Pa) |
80 |
6 Rows |
Cooling Capacity (KW) |
46.3 |
67.6 |
73.1 |
106.6 |
142.5 |
177 |
213.8 |
285.1 |
355.6 |
429.0 |
570.3 |
712.8 |
853.7 |
997.1 |
Water Flow (T/h) |
8.0 |
11.6 |
12.6 |
18.3 |
24.5 |
30.4 |
36.8 |
49.0 |
61.2 |
73.8 |
98.1 |
122.6 |
146.8 |
171.5 |
Water Resistance (Kpa) |
4.5 |
5.3 |
6.8 |
7.6 |
11.2 |
13.6 |
15.4 |
16.5 |
21.8 |
23.9 |
28.6 |
32.4 |
36.7 |
40.9 |
Air Resistance (Pa) |
120 |
8 Rows |
Cooling Capacity (KW) |
53.4 |
76.8 |
82.3 |
122.8 |
165.0 |
204.8 |
246.9 |
328.6 |
411.8 |
495.0 |
657.9 |
822.7 |
983.5 |
1145.1 |
Water Flow (T/h) |
9.2 |
13.2 |
14.1 |
21.1 |
28.4 |
35.2 |
42.5 |
56.5 |
70.8 |
85.1 |
113.2 |
141.5 |
169.2 |
197.0 |
Water Resistance (Kpa) |
5.8 |
6.9 |
9.0 |
10.2 |
14.3 |
17.3 |
18.6 |
20.3 |
25.8 |
28.9 |
32.1 |
36.8 |
42.0 |
45.1 |
Air Resistance (Pa) |
160 |
Fresh Air Condition |
Inlet Air Temperature (ºC) |
DB34/WB28 |
4 Rows |
Cooling Capacity (KW) |
69.4 |
99.8 |
113.5 |
173.0 |
229.6 |
280.1 |
344.0 |
459.7 |
574.6 |
690.2 |
921.8 |
1150.3 |
1386.4 |
1681.5 |
Water Flow (T/h) |
11.9 |
17.2 |
19.5 |
29.8 |
39.5 |
48.2 |
59.2 |
79.1 |
98.8 |
118.7 |
158.5 |
197.8 |
238.5 |
278.4 |
Water Resistance (Kpa) |
9.0 |
9.7 |
11.8 |
13.7 |
19.4 |
23.6 |
29.2 |
34.2 |
40.9 |
46.5 |
57.3 |
67.7 |
80.6 |
91.2 |
Air Resistance (Pa) |
90 |
6 Rows |
Cooling Capacity (KW) |
79.1 |
117.3 |
123.1 |
185.7 |
249.0 |
306.3 |
373.8 |
498.5 |
628.3 |
755.6 |
1011.8 |
1264.3 |
1470.3 |
1767.1 |
Water Flow (T/h) |
13.6 |
20.2 |
21.3 |
31.9 |
42.8 |
52.7 |
64.3 |
85.7 |
108.1 |
130.0 |
174.0 |
217.5 |
252.9 |
303.9 |
Water Resistance (Kpa) |
13.3 |
14.4 |
17.9 |
20.8 |
28.7 |
35.3 |
44.0 |
51.6 |
60.7 |
67.2 |
87.8 |
105.6 |
123.6 |
134.5 |
Air Resistance (Pa) |
130 |
8 Rows |
Cooling Capacity (KW) |
91.3 |
136.3 |
142.8 |
213.1 |
287.1 |
355.1 |
433.7 |
575.4 |
725.8 |
871.4 |
1170.9 |
1468.3 |
1703.3 |
2081.0 |
Water Flow (T/h) |
15.7 |
23.4 |
24.7 |
36.7 |
49.4 |
61.1 |
74.6 |
99.0 |
12.4 |
149.9 |
201.4 |
252.5 |
292.9 |
352.8 |
Water Resistance (Kpa) |
19.8 |
20.8 |
26.6 |
29.1 |
42.8 |
50.1 |
66.3 |
73.7 |
94.8 |
100.8 |
133.8 |
168.6 |
197.5 |
223.6 |
Air Resistance (Pa) |
Pict 9, 16, 33, 24, 9, 37, 35, 4 PictOld
|
Water Connection Pipe |
PictOld
|
|
PictOld 15, 9, 33, 23, 15, 30, 35, 3 PictOld
|
Condensed Water Pipe |
PictOld
|
|
|
Number of Surface Cooler |
1 |
2 |
3 |
Section of Heating |
Inlet Air Condition (ºC) |
DB15 |
Heated by Hot Water |
Inlet/Outlet Water Temp (ºC) |
60/50 |
2 Rows |
Heating Capacity (KW) |
41.7 |
55.7 |
69.8 |
104.6 |
139.6 |
174.5 |
209.3 |
279.1 |
348.9 |
418.9 |
558.2 |
697.8 |
837.47 |
977 |
Water Flow (T/h) |
3.6 |
4.8 |
6.0 |
9.0 |
12.0 |
15.0 |
18.0 |
24.0 |
30.0 |
36.0 |
48.0 |
60.0 |
72.0 |
84.0 |
Water Resistance (Kpa) |
1.8 |
2.1 |
2.5 |
2.8 |
3.8 |
4.6 |
5.5 |
6.5 |
7.4 |
8.3 |
10.5 |
12.1 |
14.4 |
17.0 |
Air Resistance (Pa) |
55 |
4 Rows |
Heating Capacity (KW) |
52.1 |
69.6 |
87.2 |
130.6 |
174.5 |
218.1 |
261.7 |
348.9 |
436.1 |
523.4 |
697.8 |
872.3 |
1046.8 |
1221.3 |
Water Flow (T/h) |
4.5 |
6.0 |
7.5 |
11.2 |
15.0 |
18.8 |
22.5 |
30.0 |
37.5 |
45.0 |
60.0 |
75.0 |
90.0 |
105.0 |
Water Resistance (Kpa) |
2.3 |
2.8 |
3.5 |
3.9 |
5.8 |
7.0 |
8.3 |
8.9 |
10.1 |
11.5 |
14.5 |
17.3 |
21.5 |
26.8 |
Air Resistance (Pa) |
80 |
|
Water Connection Pipe |
2" |
Heated by Steam |
2 Rows |
Heating Capacity (KW) |
55.1 |
74.5 |
93.6 |
140.4 |
187.2 |
234.0 |
280.7 |
374.3 |
467.9 |
561.3 |
748.5 |
935.1 |
1121.7 |
1308.3 |
Steam Pressure (Mpa) |
0.2 |
Steam Temperature (ºC) |
115 |
Air Resistance (Pa) |
55 |
Water Connection Pipe |
2" |
Heated by Electricity |
Electric Power (KW) |
6 |
12 |
18 |
27 |
36 |
45 |
54 |
72 |
90 |
108 |
144 |
180 |
216 |
252 |
Heating Capacity (KW) |
5.1 |
10.2 |
15.3 |
23.0 |
30.6 |
38.0 |
46.0 |
62.0 |
78.0 |
92.0 |
123.0 |
153.0 |
184 |
214 |
Power of Every Group (KW) |
3 |
3 |
6 |
9 |
12 |
15 |
18 |
24 |
30 |
18 |
24 |
30 |
36 |
42 |
Temperature Rise of Air (ºC) |
5.4 |
Air Resistance (Pa) |
30 |
Section of Humidifying |
Humidification Capacity (kg/h) |
10 |
20 |
30 |
45 |
60 |
75 |
90 |
120 |
150 |
180 |
240 |
300 |
360 |
420 |
Dry Steam |
Pressure (Mpa) |
0.1 |
Wet Film |
Resistance (Pa) |
20~30 |
Section of Coarse Filter |
Speed of Filtering m/s |
<1.5 |
Efficiency of Filtering |
≥5u Counting Efficiency 90%(G4) |
Original Resistance / Eventual Resistance (Pa) |
50/100 |
Section of Medium Efficiency Filter |
Speed of Filtering (m/s) |
0.3 |
Efficiency of Filtering |
≥1u Counting Efficiency 95%(F8) |
Original Resistance / Eventual Resistance (Pa) |
100/200 |
Sub-high Efficiency / High Efficiency Filter |
Installed According to the Client's Reqirement |