Air Cooled Screw Water Chillers(with heat recovery) | |||||||
Model Number | HWALR150 | HWALR200 | HWALR250 | HWALR330 | HWALR400 | ||
Cooling Capacity | KW | 150 | 182 | 245 | 322 | 388 | |
Heating Capacity | KW | 185 | 212 | 285 | 380 | 445 | |
Cooling Power Input | KW | 48.2 | 57.7 | 76 | 99 | 118 | |
Heating Power Input | KW | 47 | 56 | 74 | 97 | 113 | |
Power Supply | 380V/3N~50Hz | ||||||
Energy Control | 0~25~50~75~100% / Infinitely Variable Control | ||||||
Compressor | Type | 6+7 Semi-closed Double Screw Type | |||||
Number | 1 | 1 | 1 | 1 | 1 | ||
Refrigerant | Type | R22 (other refrigerant systems(R407C,etc) are available too.) | |||||
Way of Throttling | External Balance of Thermal Expansion Valve/ Electronic Expansion Valve | ||||||
Refrigerant Volume | kg | 48 | 62 | 74 | 85 | 115 | |
Heat Exchanger of Air Side | Internal Thread Copper Tube with Aluminium Fin | ||||||
Condensing Fan | Type | Ultra-low Noise Axial Fan | |||||
Power | KW | 1.1*4 | 1.5*4 | 1.5*6 | 1.5*8 | 1.5*10 | |
Heat Exchanger of Water Side | Type | Dry Shell and Tube | |||||
Cooling Water Flow | m³/h | 26 | 32 | 43 | 56 | 67 | |
Heating Water Flow | m³/h | 28 | 37 | 49 | 66 | 77 | |
Connection Pipe | DN80 | DN80 | DN100 | DN100 | DN100 | ||
Water Resistance | KPa | 50~60 | |||||
Partial Heat Recovery | Heating Capacity | KW | 55 | 65 | 86 | 114 | 135 |
Hot Water Volume | m³/h | 15.7 | 18.6 | 24.6 | 32.6 | 38.7 | |
Total Heat Recovery | Heating Capacity | KW | 158 | 180 | 245 | 325 | 380 |
Hot Water Volume | m³/h | 45 | 52 | 90 | 93 | 109 | |
Noise Level | dB/A | 64 | 64 | 65 | 65 | 66 | |
Dimensions | Length | mm | 2300 | 2500 | 3400 | 4400 | 5400 |
Width | mm | 2200 | 2250 | 2250 | 2250 | 2250 | |
Height | mm | 2200 | 2250 | 2250 | 2250 | 2250 | |
Notice: 1. Nominal cooling condition: inlet/outlet water temperature is 12/7ºC, the air dry/wet bulb temperature is 35/24ºC; | |||||||
2. Nominal heating condition: inlet/outlet water temperature is 40/45ºC, the air dry/wet bulb temperature is 7/6ºC. | |||||||
3. The water supply of heat recovery refers to the water volume when the water temperature increases from 20ºC to 50ºC. | |||||||
4.other refrigerant systems(R407C,etc) are available too. | |||||||
5. The above dimensions are just for reference, they maybe modified due to improvement. |