• Customized High Quality Industrial Commercial Dehumidifier Floorstanding
  • Customized High Quality Industrial Commercial Dehumidifier Floorstanding
  • Customized High Quality Industrial Commercial Dehumidifier Floorstanding
  • Customized High Quality Industrial Commercial Dehumidifier Floorstanding
  • Customized High Quality Industrial Commercial Dehumidifier Floorstanding

Customized High Quality Industrial Commercial Dehumidifier Floorstanding

Type: Rooftop Air Conditioner
Air Tube Material: Customized
Corrosion Durability: Ultrahigh
Operating Voltage: 380/400 VAC
Noise Level: Ultra Low
Application Fields: Airports,Exhibition Halls, Stadiums, etc
Customization:
Gold Member Since 2011

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
C/CFT/CST
Mounting
Floor Standing
Lifetime
10~15 years
Certification
ISO, CE, Soncap
Condition
New
Name
Customized High-Power High-Quality Industrial Dehu
Cooling Capacity
13-268kw
Refrigerant
R22/R407cr410A etc
Transport Package
Plastc+Foam+Woden Case
Specification
800-2360kgs
Trademark
Headpower
Origin
China(Mainland)
Production Capacity
500 Units/Month

Product Description

To build a perfect basement, we need to solve the problem fundamentally, and we need to design the system from many aspects, such as drainage prevention, moisture resistance, heat preservation, dehumidification, ventilation and materials.

1. Waterproof treatment must be done. When decorating, on the basis of the waterproof measures already taken by the developer, the second waterproof treatment can be carried out to prevent water seepage in the basement; the basement ceiling, floor and wall shall be waterproof.

2. Moistureproof materials must be selected. Basement is a humid place. When decorating and selecting materials, attention should be paid to waterproof mortar, wallpaper, vitrified brick and other moistureproof effects.

3. Adopt the design of ventilation and moisture dissipation. In the basement, the air circulation is very important. If possible, it is suggested to install a fresh air system to ensure that the basement can be ventilated at room temperature.

4. Install dehumidifier to absorb the excess moisture in the air of basement. Efficient dehumidification, water in the air into water drainage, to achieve the purpose of moisture-proof.

Fresh air dehumidification system

The principle of dehumidifier is that the fan sucks the moist air into the machine, and the refrigeration system of the compressor lowers the surface of the evaporator below the dew point temperature of the air. When the moist air passes through the evaporator, the water in the air will be decomposed and attached to the surface of the evaporator The water will flow along the hydrophilic platinum on the evaporator to the water tank and then to the water tank or drain pipe for drainage. After the dehumidified dry cold air is heated by the heat recovered from the condenser, the dry air will be discharged out of the machine, so as to achieve the drying effect in the wet room.

Strong dehumidification

The strong dehumidification function keeps the indoor humidity at a relatively comfortable humidity value for human body, and the relatively humid basement can also be dry and comfortable.

Fresh air ventilation

The fresh air dehumidifier can introduce fresh air, replace the dirty air, reduce the concentration of carbon dioxide and increase the oxygen content of indoor air.

In addition to haze sterilization

When the main engine is running, the fresh air or return air will pass through the purification end (primary effect filter screen, high-efficiency filter screen, etc.) in the machine, and will filter and purify the indoor and outdoor haze PM2.5, indoor toxic and harmful gases, formaldehyde, VOC, benzene series bacteria left in the decoration, so as to eliminate the mildew.

items                                                   type CFT8 CFT10 CFT16 CFT20 CFT25 CFT32 CFT40 CFT50 CFT60 CFT80 CFT100
dehumidity capacity kg/h 8 10 16 20 25 32 40 50 60 80 100
cooling capacity KW 14 16.6 28 33 42 56 66 83 99 132 165
power supply 220V/1PH-50HZ           380V/ 3PH-50HZ 380V/3PH-50HZ
protection devices high &low pressure switch,over load protector,phase order protection,internal over-heat protector ,frequent boot protector
operation and control microcomputer control automatically,failure warning,trouble self-checking, operation balance,Timer on/off 
compressor type hermetic scroll compressor
power KW 3.75 4.5 3.75×2 4.5×2 3.75×3 3.75×4 4.5×4 4.5×5 9×3 9×4 9×5
heat exchanger of air side  exchanger type copper tubes with aluminum fin
 fan type  ultra-low-noise centrifugal
air flow m3/h 2600 3200 5200 6400 7800 10800 12800 16000 19200 25600 32000
external static pressure Pa 0/100 0/120 0/150 0/180 200 220 250 280 350 350 400
motor power KW 0.55 0.75 0.55×2 0.75×2 2.2 3 4 5.5 7.5 11 15
heat exchanger of outdoor side exchanger type  hydrophilic film aluminum fins with  copper tubes
fan type  low-noise axial
air flow m3/h 5000 6000 11000 13000 17000 22000 25000 33000 39000 54000 66000
motor power KW 0.25 0.28 0.25×2 0.28×2 0.55×2 1.1×2 1.1×2 0.75×3 1.1×3 1.1×4 1.1×5
refrigerant/volume control R22/ thermostatic expansion valve
operation noise dB(A) 56 59 62 63 65 66 66 68 70 71 72
weight kg 220 240 320 380 450 520 600 680 810 980 1160
dimensions   (L×W×H) indoor unit mm  1050×600×1650 1100×600×1700 1450×650×1700 1600×800×1800 1800×800×1800 2000×850×1980 2100×900×2050 2100×1160×2200 2200×1200×2200 2400×1380×2200 2500×1600×2400
outdoor unit mm  840×840 ×950 840×840 ×950 1050×1050×1300 1050×1350×1300 1200×1350×1300 2250×1050×1150 2300×1100×1250 2300×1100×1500 2300×1200×1400 2300×2100×2000 2300×3100×2000

 

Note:                                                                                                                                                                                                                                     1. The above parameters are measured under the following conditions: indoor air temperatureDB27 ºC,WB21.2ºC; For air cooled type, outdoor air temperature DB35ºC,WB24ºC; For water cooled type, the inlet/outlet water temperature is 30ºC/35ºC.                                                                          2. The specifications are subject to change without notice for improvement.                                                                                                                    3. Any special requirements please notify us in advance.
Customized High Quality Industrial Commercial Dehumidifier FloorstandingCustomized High Quality Industrial Commercial Dehumidifier FloorstandingCustomized High Quality Industrial Commercial Dehumidifier FloorstandingCustomized High Quality Industrial Commercial Dehumidifier FloorstandingCustomized High Quality Industrial Commercial Dehumidifier FloorstandingCustomized High Quality Industrial Commercial Dehumidifier FloorstandingCustomized High Quality Industrial Commercial Dehumidifier Floorstanding
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2011

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Number of Employees
76
Year of Establishment
2004-12-28