• Air-Cooled Cleaning Explosion-Proof Type Dehumidifier
  • Air-Cooled Cleaning Explosion-Proof Type Dehumidifier
  • Air-Cooled Cleaning Explosion-Proof Type Dehumidifier
  • Air-Cooled Cleaning Explosion-Proof Type Dehumidifier
  • Air-Cooled Cleaning Explosion-Proof Type Dehumidifier
  • Air-Cooled Cleaning Explosion-Proof Type Dehumidifier

Air-Cooled Cleaning Explosion-Proof Type Dehumidifier

After-sales Service: Spare Parts
Warranty: 18 Months
Type: Air Handling Unit
Air Tube Material: FRP
Corrosion Durability: Ultrahigh
Operating Voltage: 380/400 VAC
Samples:
US$ 5000/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Gold Member Since 2011

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
CFTB/SWB
Noise Level
Ultra Low
Application Fields
Petroleum, Chemical Industry, Ships
Mounting
Floor Standing
Lifetime
15~20 years
Certification
ISO, CE
Condition
New
Refrigerant
R22/407c/410A/R134A
Product Name
Air-Cooled Cleaning Explosion-Proof Type Dehumidif
Cooling Capacity
10-200kw
Transport Package
Stretch Roll Film, EPE, Wooden Package
Specification
Customize
Trademark
Head-Power
Origin
China(Mainland)
Production Capacity
600 Sets/Month

Product Description

Air-Cooled Cleaning Explosion-Proof Type Dehumidifier

Industrial explosion-proof air conditioner is an air-conditioning device with explosion-proof function that can be applied to many fields in industry.
Explosion-proof air conditioners are a kind of explosion-proof electrical appliances, mainly used for refrigeration and heating in flammable and explosive environments such as petroleum, chemical, oil depot, offshore oil platforms, etc. The appearance and usage of explosion-proof air conditioners are the same as ordinary air conditioners. Explosion-proof air conditioners are divided into high temperature, low temperature, extra high temperature, and extra low temperature according to the working environment.
Explosion-proof air-conditioning products must meet the relevant national explosion-proof standards before they are allowed to enter the market. The current nationally announced implementation standards for explosion-proof products are:
GB3836.1-2000 Electrical Equipment for Explosive Gas Atmosphere Part 1: General Requirements
GB3836.2 -2000 Electrical Equipment for Explosive Gas Atmosphere Part 2: Flameproof "d"
GB3836.4 -2000 Electrical Equipment for Explosive Gas Atmosphere Part 2: Intrinsically Safe "ib"
GB3836.9-2006 Electrical Equipment for Explosive Gas Atmosphere Part 9: Encapsulated Type "m"
GB3836.15-2000 Electrical equipment for explosive gas atmospheres Part 15: Electrical installation in hazardous locations (except coal mines)
JB/10538-2005 "Explosion-proof dehumidifier and air conditioner"
This explosion-proof air conditioner is composed of indoor unit and outdoor unit connecting pipes. The following is a schematic diagram of the vertical air conditioner:
Air inlet: The air in the room is sucked in from this, and dust is removed through the air filter.
Air outlet: The conditioned air is blown out from here.
Drain pipe: The moisture in the room is discharged from the drain pipe through which small water droplets are generated by the condenser.
Connecting pipe: The indoor unit and the outdoor unit are connected by copper pipes, through which the refrigerant circulates.
Outdoor unit: The outdoor unit is composed of compressor, fan, heat exchanger, capillary tube (electronic expansion valve) and other electrical components.
Temperature control switch: control the power on and off, select cooling and heating and adjust the set temperature, and control the indoor temperature. Working principle of air conditioner (heat pump type)

 
Ducted Type Air Conditioner(Floorstanding duct mounted type)
Model HAM02FBG HAL12X
Unit performance   Cooling capacity kw 4 8
Heating capacity kw 0 0
*Electric heating kw 0 0
Air flow m3/h 1000 1500
External static pressure Pa 0 0
Power Supply 380V/3PH/50HZ
Refrigerant Type R410A
Volume control Thermal expansion valve
Compressor Type  
Power  kw 3.75*2 4.5*2
     
Evaporator Type Copper tubes aluminum fins
Fin type aluminum fins
Indoor unit Fan Type Low noise centrifugal fan
Driving method belt-drive belt-drive
Power kw 1.1 2.2
Unit Dimension L mm 1250 1450
mm 600 800
mm 1800 1800
Weight kg 160 225
Noise level  dB/(A) <56 <60
    Model   SW10 SW12
Outdoor unit  Compressor Type  
Power kw 3.75*2 4.5*2
volume control     expansion valve expansion valve
refrigerant charge Refrigerant charge   5*2 5.6*2
Condenser Type Copper tube with aluminum fins
Fin type Slotted-type two-way aluminum fin
Blower Type Axial fan 
Driving method direct drive 
Power  kw 0.9 1.1
Unit Dimension L mm 750 1550
mm 600 700
mm 1800 2000
Weight kg 80 245
Noise level  dB(A) 47 58


Air-Cooled Cleaning Explosion-Proof Type Dehumidifier
Air-Cooled Cleaning Explosion-Proof Type Dehumidifier
Air-Cooled Cleaning Explosion-Proof Type Dehumidifier
Air-Cooled Cleaning Explosion-Proof Type Dehumidifier
Air-Cooled Cleaning Explosion-Proof Type Dehumidifier
Air-Cooled Cleaning Explosion-Proof Type Dehumidifier


 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2011

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Number of Employees
76
Year of Establishment
2004-12-28